Project Description
Technical specification
Ordering number: 40120
Connecting voltage: 5-50 V ss. / 5-50 V stř.
Connecting current: 0,2 A
Max. connecting power: 10 W/VA
Indication: yes
Type of cable: Semoflex 2 x 0.24, diam. 3,6 mm
Length of sensor: 26 mm
Storage temperature: -20°C až +65°C
Working temperature: -30°C až +80°C
Protecting: IP 54
Standard length of cable: 2 m
Sensor bushing material: Aluminium ČSN 42 7710
Magnetic inductance 2 mm far from bushing: 100 ± 50 x 10-4 T to connect(inf. 20 Az)
Chart of SP sensors (dis)connecting
Example of magnetic toroid:
Parameters of protecting parts: D=69 mm, d=46 mm, h=8 mm, mat.: D300
Hm=9600 Acm-1, Hc=2200 Acm-1, axial magneting
Parameters of contacts of SP-x sensors are defined for ohmical load reading. It has to be diode, RC circuit, overvoltage protection (varistor, transil) or its combination used for correct function of SP sensors. More info see below.
Sensors labeling SP(H)-X.uu.x.i / l
SP Sensor for pneumatic valve (contact)
SPH Sensor for pneumatic valve (contactless – Hall sensor)
X Type of bushing 2, 4, 5, 6
uu Max. connecting voltage: 05…50 V, 25…250 V
x Type of connecting voltage: no sign or x…DC and AC, y…only AC, y…only DC
i Max. connecting current: no sign…max. 0,5 A; 0,1…0,15 A; 0,2…0,2 A; 0,5…0,5 A; 0,7…0,7 A; 3…3 A
l Length of cable: no sign means 2 m (standard)
Do you have a question? Contact us.